© S.
A. Velikin, A. M. Snegirev
Vilyui Permafrost
Research, Permafrost Institute Siberian Branch, Russian Academy of Sciences,
Russia
In
the paper is presented and discussed the examples of successful
use of various electrometric and thermometric techniques to
study and monitor the state of the right-bank contiguity of
the dam at the Vilyui hydroelectric power plant, wich environmental
in Western Jakutia.
The examples show the efficacy of geophysical methods to study
the filtering flow and the necessity of a wide application of
them in the monitoring systems in cryolithozone.